AutoOperatorOpeningSwing
AutoOperatorOpeningSwing
backcheckAngleInDegreesint
Angle at which door begins to deaccelerate to backcheck speed. Set to lower angles for heavier doors.
backcheckSpeedobject
Opening speed from backcheck angle to full open position. Set to lower speeds for heavier doors.
Show child attributes
forceint
Adjusts max opening force allowed by device. 1 is the least force and 10 is strongest. Range 1 to 10 unitless. Higher settings may be needed for external doors which may need to drive open against strong winds.
speedint
Opening speed from closed to backcheck angle. 1 is slowest speed, 10 is fastest. Range 1 to 10 unitless. Actual door speed may vary based on many factors. If Opening Force setting is too low, it can limit the Opening Speed.